SolarMax 3000P 3kW Solar Inverter
***ย We use Sendle for shipping – shipping cost will be determined at Checkout ***
*** Pick Up also welcome from Sylvania, NSW ***
******************************************************************************************************
***ย PLEASE NOTE: ***
A large quantity of these units have been acquired from a manufacturer liquidation.
The approval for all SolarMax inverters on the CEC Approved List expired on 4/11/2018,
however we have documentation from the CEC stating that these can still be installed
in existing solar systems where the inverter will be replacing aย similarย inverter.
Please notify your electrician of this information if required.
******************************************************************************************************
Manufacturer Information:
Grid Connected, 1x String, 1x MPPT, Output 230V, 50Hz
Solar Power Inverter 3000 Watts
– Swiss-Made & Manufactured by Sputnik Engineering AG
– These units are superior quality and built with a full metal casing
– High reliability and long-term durability
– Easy installation
– Maximum efficiency of up to 98 percent using HERIC topology
– Suitable for both indoor and outdoor installations
Included in the box:
– Solar inverter
– Printed instruction manual
– Mounting bracket and screws
Input values:
MPP voltage range: 310 – 480 V
Total MPP operating voltage range: 120 – 580 V
Minimum DC voltage: 120 V
Maximum DC voltage: 600 V
Maximum DC current: 10A
Number of MPP trackers: 1
Number of string connections: 1
Connection type: Wieland PST40i1 (MC4 identical in design)
Output values:
Rated output power: 3,000 W
Maximum apparent output power: 3,000 VA
Maximum AC current: 13.5 A
Nominal mains voltage/range: 230 V / 184 V – 276 V
Mains nominal frequency/range: 50 Hz / 45 Hz – 55 Hz
Power factor cos(f): Adjustable from 0.8 overexcited to 0.8 underexcited
Distortion factor at rated output power: < 3 %
Connection type: Terminal (2.5 10 mm2)
Grid connection: Single phase (L / N / PE)
Physical Specs:
Weight:ย Approx. 17kg per unit
Dimensions:ย 476mm (width) x 360mm (height) x 180mm (depth) per unit
SolarMax 2000P | SolarMax 3000P | SolarMax 4000P | SolarMax 4600P | SolarMax 5000P | |
Input values | |||||
MPP voltage rangeโ1) | 210 .. 480 V | 310 .. 480 V | 210 .. 480 V | 240 .. 480 V | 260 .. 480 V |
Total MPP operating voltage range |
120 … 580 V | 120 … 580 V | 120 … 580 V | 120 … 580 V | 120 … 580 V |
Minimum DC voltage | 120 V | 120 V | 120 V | 120 V | 120 V |
Maximum DC voltage | 600 V | 600 V | 600 V | 600 V | 600 V |
Maximum DC current | 10 A | 10 A | 10 + 10 A | 10 + 10 A | 10 + 10 A |
Number of MPP trackers | 1 | 1 | 2 | 2 | 2 |
Number of string connections | 1 | 1 | 2 | 2 | 2 |
Connection type | Wieland PST40i1 (MC4 identical in design) | ||||
Output values | |||||
Rated output power2) | 2โ000 W | 3โ000 W | 4โ000 W | 4โ600 W | 5โ000 W |
Maximum apparent output power2) | 2โ000 VA | 3โ000 VA | 4โ000 VA | 4โ600 VA | 5โ000 VA |
Maximum AC current | 9 A | 13.5 A | 17.5 A | 22 A | 22 A |
Nominal mains voltage / range | 230 V / 184 .. 276 V | ||||
Mains nominal frequency / range | 50 Hz / 45 Hzโฆ55 Hz | ||||
Power factor cos(ฯ) | Adjustable from 0.8 overexcited to 0.8 underexcited | ||||
Distortion factor at rated output power | < 3 % | ||||
Connection type | Terminal (2.5 โ 10 mm2) | ||||
Grid connection | Single phase (L / N / PE) | ||||
Power input at night | 0W | ||||
Efficiency | |||||
Maximum efficiency | 97.5 % | 97.5 % | 98.0 % | 98.0 % | 98.0 % |
Europ. Efficiency | 97.0 % | 97.0 % | 97.5 % | 97.5 % | 97.5 % |
Ambient conditions | |||||
Protection type | IP65 | ||||
Ambient temperature range (for rated power output) | -20 ยฐCโฆ+60 ยฐC (+45ยฐC) | ||||
Relative humidity | 0โฆ100% (condensation) | ||||
Max. operating level above sea level | 2000m (without derating) | ||||
Fire protection class | V0 | ||||
Noise emissions | < 30 dB(A) (โ 1.5 m) | ||||
Configuration | |||||
Display | Graphic LC display with backlighting and status LED | ||||
Inverter topology | HERICยฎ, transformerless | ||||
DC disconnector | Integrated | ||||
Data logger | Energy yield, peak output and operating hours of the last 31 days, 12 months, 10 years. Performance curves of the last 7 days. |
||||
Fault current monitoring | Internal, AC/DC sensitive | ||||
Housing / service cover | Aluminium / plastic ASA+PC | ||||
Surge protection DC and AC | Requirement class D (VDE 0675-6) and/or type 3 (EN 61643-11) | ||||
Standards & guidelines | |||||
CE-compliant | Yes | ||||
EMC | EN 61000-3-2 / EN 61000-3-3 / EN 61000-3-11 / EN 61000-3-12 / EN 61000-6-2 / EN 61000-6-3 |
||||
Grid connection |
VDE 0126-1-1 A1:2012 / VDE-AR-N 41053)/ CEI 0-214)ย / RD 661 / RD 1699 / G83/2 / |
||||
Device safety | IEC/ EN 62109-1/ -2 | ||||
Interfaces | |||||
Data communication | RS485 / Ethernet (Plug&Play) | ||||
Status signalling contact | With optional I/O module | ||||
Connection ripple control signal receiver | |||||
Connection of external lightning protection control | |||||
Connection external grid monitoring | |||||
Connection of external energy meter | |||||
Weight & dimensions | |||||
Weight | 17 kg | 17 kg | 19 kg | 19 kg | 19 kg |
Dimensions in mm (W x H x D) | 476 x 360 x 180mm | ||||
1)ย For AC rated power output |
All rights, amendments and errors reserved |